ICOS

Dataset of atmospheric observations from Krakow, Poland

Collection
10.18160/8DSK-R4JS (target, metadata)
This dataset contains three types of observations carried out within the CoCO2 project: A: Urban ecosystem flux time series The urban ecosystem flux tower is installed on the roof of the Faculty of Physics and Applied Computer Science building. The elevation of instruments installed on the top of the tower is approximately 40 m.a.g.l. The measurement system consists of a Gill Windmaster sonic anemometer, LICOR LI7500DS open path CO2/H2O analyser, a Huxeflux NR01 net radiometer, and a SmartFlux 3 datalogger. It is supplemented by a VAISALA WXT520 combined weather station delivering Biomet data for the system. B: Vertical profiles of the CO2 and CH4 mixing ratios from the Krakow urban area Vertical profiles of CO2 and CH4 within the urban boundary layer of Krakow city were performed using two different platforms. The first platform was a tethered touristic balloon operated by the Balon Widokowy Sp. z o.o. company in the city centre. C: Diurnal variability of the isotopic composition of atmospheric CO2 The last part of the data set contains the isotopic analysis of flask samples collected every 4 hours during flight campaigns. Each sample was collected using an automatic flask sampler (shown in Fig. 9) in pair of glass flasks (1 l and 3 l capacity) by flushing with dry air. The air inlet was installed on the roof of Faculty building ca. 25 m a.g.l
This dataset contains three types of observations carried out within the CoCO2 project: A: Urban ecosystem flux time series The urban ecosystem flux tower is installed on the roof of the Faculty of Physics and Applied Computer Science building. The elevation of instruments installed on the top of the tower is approximately 40 m.a.g.l. The measurement system consists of a Gill Windmaster sonic anemometer, LICOR LI7500DS open path CO2/H2O analyser, a Huxeflux NR01 net radiometer, and a SmartFlux 3 datalogger. It is supplemented by a VAISALA WXT520 combined weather station delivering Biomet data for the system. B: Vertical profiles of the CO2 and CH4 mixing ratios from the Krakow urban area Vertical profiles of CO2 and CH4 within the urban boundary layer of Krakow city were performed using two different platforms. The first platform was a tethered touristic balloon operated by the Balon Widokowy Sp. z o.o. company in the city centre. C: Diurnal variability of the isotopic composition of atmospheric CO2 The last part of the data set contains the isotopic analysis of flask samples collected every 4 hours during flight campaigns. Each sample was collected using an automatic flask sampler (shown in Fig. 9) in pair of glass flasks (1 l and 3 l capacity) by flushing with dry air. The air inlet was installed on the roof of Faculty building ca. 25 m a.g.l
Mirosław Zimnoch, Piotr Sekuła, Alina Jasek-Kamińska, Alicja Skiba, Michał Gałkowski, Łukasz Chmura, Jakub Bartyzel, Paweł Jagoda, Michał Kud, Jarosław Nęcki
2023
AGH University of Krakow
dry air CO2 mole fraction, dry air CH4 mole fraction, eddy covariance, vertical profile, balloon sonde, 14CO2, radiocarbon CO2, 13CO2, C18O2
Zimnoch, M., Sekuła, P., Jasek-Kamińska, A., Skiba, A., Gałkowski, M., Chmura, Ł., Bartyzel, J., Jagoda, P., Kud, M., Nęcki, J., 2023. Observational datasets of urban CO2 fluxes, atmospheric vertical profiles of CO2 and CH4 and 14CO2, and isotopic composition of atmospheric CO2 at Krakow, Poland; period 2021-2023; part of the CoCO2 project . https://doi.org/10.18160/8DSK-R4JS
BibTex
@misc{https://doi.org/10.18160/8dsk-r4js,
  doi = {10.18160/8DSK-R4JS},
  url = {https://meta.icos-cp.eu/collections/laoLFrAmJVuG3iuErWA3UWtL},
  author = {Zimnoch, Mirosław and Sekuła, Piotr and Jasek-Kamińska, Alina and Skiba, Alicja and Gałkowski, Michał and Chmura, Łukasz and Bartyzel, Jakub and Jagoda, Paweł and Kud, Michał and Nęcki, Jarosław},
  keywords = {dry air CO2 mole fraction, dry air CH4 mole fraction, eddy covariance, vertical profile, balloon sonde, 14CO2, radiocarbon CO2, 13CO2, C18O2},
  title = {Observational datasets of urban CO2 fluxes, atmospheric vertical profiles of CO2 and CH4 and 14CO2, and isotopic composition of atmospheric CO2 at Krakow, Poland; period 2021-2023; part of the CoCO2 project },
  publisher = {AGH University of Krakow},
  year = {2023},
  copyright = {CC BY 4.0}
}
RIS
TY  - GEN
T1  - Observational datasets of urban CO2 fluxes, atmospheric vertical profiles of CO2 and CH4 and 14CO2, and isotopic composition of atmospheric CO2 at Krakow, Poland; period 2021-2023; part of the CoCO2 project 
AU  - Zimnoch, Mirosław
AU  - Sekuła, Piotr
AU  - Jasek-Kamińska, Alina
AU  - Skiba, Alicja
AU  - Gałkowski, Michał
AU  - Chmura, Łukasz
AU  - Bartyzel, Jakub
AU  - Jagoda, Paweł
AU  - Kud, Michał
AU  - Nęcki, Jarosław
DO  - 10.18160/8DSK-R4JS
UR  - https://meta.icos-cp.eu/collections/laoLFrAmJVuG3iuErWA3UWtL
AB  - This dataset contains three types of observations carried out within the CoCO2 project:
A: Urban ecosystem flux time series
The urban ecosystem flux tower is installed on the roof of the Faculty of Physics and Applied Computer Science building. The elevation of instruments installed on the top of the tower is approximately 40 m.a.g.l. The measurement system consists of a Gill Windmaster sonic anemometer, LICOR LI7500DS open path CO2/H2O analyser, a Huxeflux NR01 net radiometer, and a SmartFlux 3 datalogger. It is supplemented by a VAISALA WXT520 combined weather station delivering Biomet data for the system.
B: Vertical profiles of the CO2 and CH4 mixing ratios from the Krakow urban area
Vertical profiles of CO2 and CH4 within the urban boundary layer of Krakow city were performed using two different platforms. The first platform was a tethered touristic balloon operated by the Balon Widokowy Sp. z o.o. company in the city centre.
C: Diurnal variability of the isotopic composition of atmospheric CO2
The last part of the data set contains the isotopic analysis of flask samples collected every 4 hours during flight campaigns. Each sample was collected using an automatic flask sampler (shown in Fig. 9) in pair of glass flasks (1 l and 3 l capacity) by flushing with dry air. The air inlet was installed on the roof of Faculty building ca. 25 m a.g.l
KW  - dry air CO2 mole fraction
KW  - dry air CH4 mole fraction
KW  - eddy covariance
KW  - vertical profile
KW  - balloon sonde
KW  - 14CO2
KW  - radiocarbon CO2
KW  - 13CO2
KW  - C18O2
PY  - 2023
PB  - AGH University of Krakow
ER  -

Content

1

Statistics

0