ICOS OTC SOOP Release from Polarstern
2020-03-01–2020-04-01
11676/ZP5jFmXd2r7AwgkqW6HU-PWy (link)
Standard gas 4 is approximately 7 ppm lower than the calibrated value, and more variable than the other 2 gasses. This might indicate that there was a small leakage at the regulator or on the connecting line going to the GO.
The error of this is unclear
Data processed using QuinCe v23.3.3
Hoppema, M., van Heuven, S., Roden, N., Becker, H., Olivier, L. (2025). ICOS OTC SOOP Release from Polarstern, 2020-03-01–2020-04-01, ICOS RI, https://hdl.handle.net/11676/ZP5jFmXd2r7AwgkqW6HU-PWy
BibTex
@misc{https://hdl.handle.net/11676/ZP5jFmXd2r7AwgkqW6HU-PWy,
author={Hoppema, Mario and van Heuven, Steven and Roden, Nicholas and Becker, Hauke and Olivier, Léa},
title={ICOS OTC SOOP Release from Polarstern, 2020-03-01–2020-04-01},
year={2025},
url={https://hdl.handle.net/11676/ZP5jFmXd2r7AwgkqW6HU-PWy},
publisher={Ocean Thematic Centre},
copyright={http://meta.icos-cp.eu/ontologies/cpmeta/icosLicence},
pid={11676/ZP5jFmXd2r7AwgkqW6HU-PWy}
}
RIS
TY - DATA T1 - ICOS OTC SOOP Release from Polarstern, 2020-03-01–2020-04-01 ID - 11676/ZP5jFmXd2r7AwgkqW6HU-PWy PY - 2025 UR - https://hdl.handle.net/11676/ZP5jFmXd2r7AwgkqW6HU-PWy PB - Ocean Thematic Centre AU - Hoppema, Mario AU - van Heuven, Steven AU - Roden, Nicholas AU - Becker, Hauke AU - Olivier, Léa ER -
06AQ20200301.csv
8 MB (8557042 bytes)
39916
2
Acquisition
2020-03-01 00:01:03
2020-04-01 00:00:19
Production
2025-01-20 13:09:48
Previewable variables
| Name | Value type | Unit | Quantity kind | Preview |
|---|---|---|---|---|
| TIMESTAMP | time instant, UTC | |||
| Longitude | longitude | ° | angle | Preview |
| Latitude | latitude | ° | angle | Preview |
| Temp [degC] | water temperature | °C | temperature | Preview |
| Temp [degC] QC Flag | quality flag (int) | |||
| P_sal [psu] | practical salinity | psu | portion | Preview |
| P_sal [psu] QC Flag | quality flag (int) | |||
| xCO2 in atmosphere [umol mol-1] | CO2 (dry air mole fraction) | µmol mol-1 | portion | Preview |
| Atmospheric Pressure [hPa] | air pressure | hPa | pressure | Preview |
| Atmospheric Pressure [hPa] QC Flag | quality flag (int) | |||
| pCO2 [uatm] | CO2 partial pressure (water), SST | µatm | pressure | Preview |
| pCO2 [uatm] QC Flag | quality flag (int) | |||
| fCO2 [uatm] | CO2 fugacity (water), SST | µatm | pressure | Preview |
| fCO2 [uatm] QC Flag | quality flag (int) | |||
| pCO2 in atmosphere [uatm] | CO2 partial pressure (air) | µatm | pressure | Preview |
| pCO2 in atmosphere [uatm] QC Flag | quality flag (int) | |||
| fCO2 in atmosphere [uatm] | CO2 fugacity (air) | µatm | pressure | Preview |
| fCO2 in atmosphere [uatm] QC Flag | quality flag (int) |
Statistics
57
4
Technical information
1, 2, 9
64fe631665dddabec0c2092a5ba1d4f8f5b23bb8be90f93695b98eb5d6c6f6e6
ZP5jFmXd2r7AwgkqW6HU+PWyO7i+kPk2lbmOtdbG9uY
ICOS